Nurse Call Monitoring System- Digital Series D-20/ D-30

Nurse Call Monitoring System- Digital Series D-20/ D-30

BPS offers Digital Call indicator and Monitoring Systems for Hospitals and Nursing Homes.
The system is designed updated and adopted to changing requirements of hospitals by our in house team having 15 years of experience.
These are installed in many leading hospitals for years and are working with full satisfaction of each hospital. Very simple to install and maintain.

System Over View:
Each bed is provided with call station board consisting of Bed push
confirmation light and re-set push. The patient can make call form
the push switch. On receipt of call at the Digital Display Board,
Confirmation Light on the Call Station will be on. This ensures that
there is no problem in wiring. The call received at Display Board can
only be re-set by the attending nurse from the re-set push provided
at the bed side of patient (Call Station Board). On attending the call,
the confirmation light and the bed number at the monitor will be
switched off.
If any call remains pending over a set period the particular number will be hi-lighted by flushing the digit & buzzer installed at the floor in-charge/matron will be activated.This will help in avoiding any negligence in services.

The system will comprise of
a) Call Station Board,                         nurse_call
b) Door Indicator,
c) Digital Display board,
d) Data Logger Card
e) UPS system

Call Station Board
is consisting of Bed push confirmation light and re-set push. It is designed for standard modular box.

Door Indicator:
is consisting of cluster of LEDs mounted in specially designed cabinet. It has Tangle/ Round Red acrylic cover. It may be installed out side the room. It starts flushing if any call in the room is pending. This helps the Nurses moving by to attend immediately even before going to the Nurses Station.

Digital Display board:
The Digital display board is call monitor console which is installed at the Nurse center. All Call received from any bed will be displayed by the respective bed number by 3 digit display. Select the display board as per total no of beds, toilets etc to be covered by one Nurse Station. It has soft buzzer which alerts the attendment on receipt of any new calls.

Call Station Board
is consisting of Bed push confirmation
light and re-set push. It is designed
for standard modular box.

Data Logger Card:
This is a add-on card to connect the display bard with any standard computer. With this add on card all events can be recorded. Call received from each bed is stamped with time of call and on attendance also it is stamped with time. Data thus
generated helps the Hospital Management in taking appropriate decisions. The card is supported with specially developed softwar which is installed in the computer.

UPS system.
The system has its own specially designed UPS. It is consisting of a SMF type 12 v 7 ah battery,automatic battery charger and allied accessories.

Unique advantages are:

Low voltage operation:
The incoming mains is converted to 12 V.D.C. in the Power Supply section and  patient is not put to danger even due to accidental snatching of wires.

Digital Display of Bed Nos:
with 2-3 digit Bright LED displays,bed number can be easily noticed from a distance.

Non Attendance timer:
Each call received activates a built in timer and after a specified time, it activates a Buzzer.

Battery backup:
To facilitate making call even during power cut, the system is provided with a battery backup.

Re-set at patients bed:
To re-set, the nurse or attendant has to press a button installed near the patient. This ensures attendance.

Cost effective solution:
This system is very cost effective for installation and maintenance

Computer Connectivity :
with add-on Card, the system can record each event and helps management in taking appropriate and logical decision.

Ordering information BPS D20 / D30 Digital Nurses Call Monitoring System.

       Item                         Description    Model No.    Quatity     requried

Call

station

Board

With 3 " x 3" MS Box, Acralic cover,
confirmation Light, Re-set push &
Bed Push with 2 meter flexible wire
BNCM-PB1 each bed = 1 set
With 3 " x 3" MS Box, Modular cover,
confirmation Light, Re-set push &
Bed Push with 2 meter flexible wire
BNCM-PB2 (PB1 or PB2)

   Door

Indicator

with 8 Nos Red LEDs, Red Acrylic cover
suitable for connecting up to 8 beds
in one room
BNCM-DU-1

    Optional

         for

       each

      room

with 3 colour LEDs, Flash/ study / Off
functions, Acknowledge Push, Acralic
cover suitable for connecting up to 4
beds in one room
BNCM-DU-2

 Digital

 Display

  Board

   with

  2digit

 display

with one No 2 Digit display card, Acralic cover,in MS box of 275 x 125 x 50 mm BNCM-D2CA up to 6 beds
with two No. 2 Digit display card, Acralic cover,in MS box of 275 x 225 x 50 mm BNCM-D2CB up to 12 beds
with three No.2 Digit display card, Acralic cover,in MS box of 300 x 325 x 50 mm BNCM-D2CC up to 18 beds
with four No. 2 Digit display card, Acralic cover,in MS box of 300 x 460 x 50 mm BNCM-D2CD up to 24 beds
with five No.2 Digit display card, Acralic cover,in MS box of 350 x 550 x 50 mm BNCM-D2CE up to 30 beds
with six No.2 Digit display card, Acralic cover,in MS box of 350 x 6000 x 50 mm BNCM-D2CF up to 36 beds
  Digital

 Display

  Board

    with

   3digit

  display
with oneNo. 3 Digit display card, Acralic cover,in MS box of 300 x 125 x 50 mm BNCM-D3CA up to 5 beds
with two No.3 Digit display card, Acralic cover,in MS box of 300 x 225 x 50 mm BNCM-D3CB up to10 beds
with three No.3 Digit display card, Acralic cover,in MS box of 300 x 350 x 50 mm BNCM-D3CC up to 15 beds
with four No.3 Digit display card, Acralic cover,in MS box of 300 x 450 x 50 mm BNCM-D3CD up to 20 beds
with fiveNo.3 Digit display card, Acralic cover,in MS box of 300 x 550 x 50 mm BNCM-D3CE up to 25 beds
with six No. 3 Digit display card, Acralic cover,in MS box of 600 x 475 x 50 mm BNCM-D3CF up to 30 beds
       Data Logger  card
Computer interferance card with softwar fitted in enclosure BNCM-DLC -1 up to 36 beds
.UPS sytem Power supply with Automatic Battery charger, SMF 12 V. 7 AH battery
BNCMUPS1 up to 36 beds=1 set
  Wires from
    bed to
       call
   station

       2 pair telephone wire as per distance from beds
        to call station


 

Search

SHARE

AddThis Social Bookmark Button

Contact Us


Email:
Subject:
Message+ Contact Number:
How many eyes a typical person has?

You are here: Home Nurses Call monitoring system Nurse Call Monitoring System- Digital Series D-20/ D-30

Power Services

33, Phears Lane, Kolkata  - 700073, West Bengal, India
Ph.: +91 033 22370508, +91 033 22360575
Fax: +91 033 22259090,email: info@indiapowerhouse.net

Baid Power Services Pvt. Ltd

152, Block-B, Lake Town, Kolkata - 700089, West Bengal, India
Ph: +91 033 25210322, Fax: +91 033 25343662
email: info@indiapowerhouse.net, Web: www.indiapowerhouse.com

 

"; urchinTracker();