Nurse Call Monitoring System Digital Series D-20/D-30
BPS offers Digital Call indicator and Monitoring Systems for Hospitals and Nursing Homes.
The system is designed updated and adopted to changing requirements of hospitals by our in house team having 15 years ofexperience.
These are installed in many leading hospitals for years and are working with full satisfaction of each
hospital.
Very simple to install and maintain.
Description
System Over View:
Each bed is provided with call station board consisting of Bed push confirmation light and re-set push. The patient can make call form the push switch. On receipt of call at the Digital Display Board, Confirmation Light on the Call Station will be on. This ensures that there is no problem in wiring.
The call received at Display Board can only be re-set by the attending nurse from the re-set push provided at the bed side of patient (Call Station Board). On attending the call, the confirmation light and the bed number at the monitor will be switched off.
If any call remains pending over a set period the particular number will be hi-lighted by Flushing the digit & buzzer installed at the floor in-charge/ matron will be activated. This will help in avoiding any negligence in services.
The system will comprise of
a) Call Station Board,
b) Door Indicator,
c) Digital Display board,
d) Data Logger Card
e) UPS system.
Call Station Board : is consisting of Bed push confirmation light and re-set push. It is designed for standard modular box. |
Door Indicator : is consisting of cluster of LEDs mounted in specially designed cabinet. It has Tangle/ Round Red acrylic cover. It may be installed out side the room. It starts flushing if any call in the room is pending. This helps the Nurses moving by to attend immediately even before going to the Nurses Station. |
Call Indicator Board : The Call Indicator Board is to be installed at the Nurse center. Call received from any bed will be displayed by the respective indicator with Green Led against bed number marked |
Digital Display board : The Digital display board is call monitor console which is installed at the Nurse center. All Call received from any bed will be displayed by the respective bed number by 3 digit display. Select the display board as per total no of beds, toilets etc to be covered by one Nurse Station. It has soft buzzer which alerts the attendment on receipt of any new calls. |
Data Logger Card: This is a add-on card to connect the display bard with any standard computer. With this add on card all events can be recorded. Call received from each bed is stamped with time of call and on attendance also it is stamped with time. Data thus generated helps the Hospital Management in taking appropriate decisions. The card is supported with specially developed software which is installed in the computer. |
UPS : The system has its own specially designed UPS. It consists of a SMF type 12 v 7 ah battery, automatic battery charger and allied accessories. |
Unique advantages are
Low voltage operation:The incoming mains is converted to 12 V.D.C. in the Power Supply section and patient is not put to danger even due to accidental snatching of wires.
Digital Display of Bed Nos:with 2-3 digit Bright LED displays, bed number can be easily noticed form a distance.
Non Attendance timer:Each call received activates a built in timer and after a specified time, it activates a Buzzer.
Battery backup:To facilitate making call even during power cut, the system is provided with a battery backup.
Re-set at patients bed:To re-set, the nurse or attendant has to press a button installed near the patient. This ensures attendance.
Cost effective solution:This system is very cost effective for installation and maintenance.
Computer Connectivity : with add-on Card, the system can record each event and helps management in taking appropriate and logical decision.
Ordering information BPS D20 / D30 Digital Nurses Call Monitoring System.
Item | Description | Model No. | Quatity requried |
Call station Board |
With 3 ” x 3″ MS Box, Acralic cover,confirmation Light, Re-set push & Bed Push with 2 meter flexible wire | BNCM-PB1 | each bed = 1 set |
With 3 ” x 3″ MS Box, Modular cover,confirmation Light, Re-set push & Bed Push with 2 meter flexible wire | BNCM-PB2 | (PB1 or PB2) | |
Door Indicator |
with 8 Nos Red LEDs, Red Acrylic cover suitable for connecting up to 8 beds in one room | BNCM-DU-1 | Optional for each room |
with 3 colour LEDs, Flash/ study / Off functions, Acknowledge Push, Acralic cover suitable for connecting up to 4 beds in one room | BNCM-DU-2 | ||
Digital Display Board with 2 digit display |
with one No 2 Digit display card, Acralic cover, in MS box of 275 x 125 x 50 mm | BNCM-D2CA | up to 6 beds |
with two No. 2 Digit display card, Acralic cover, in MS box of 275 x 225 x 50 mm | BNCM-D2CB | up to 12 beds | |
with three No.2 Digit display card, Acralic cover, in MS box of 300 x 325 x 50 mm | BNCM-D2CC | up to 18 beds | |
with four No. 2 Digit display card, Acralic cover, in MS box of 300 x 460 x 50 mm | BNCM-D2CD | up to 24 beds | |
with five No.2 Digit display card, Acralic cover,in MS box of 350 x 550 x 50 mm | BNCM-D2CE | up to 30 beds | |
with six No.2 Digit display card, Acralic cover,in MS box of 350 x 6000 x 50 mm | BNCM-D2CF | up to 36 beds | |
Digital Display Board with 3 digit display |
with oneNo. 3 Digit display card, Acralic cover, in MS box of 300 x 125 x 50 mm | BNCM-D3CA | up to 5 beds |
with two No.3 Digit display card, Acralic cover, in MS box of 300 x 225 x 50 mm | BNCM-D3CB | up to 10 beds | |
with three No.3 Digit display card, Acralic cover, in MS box of 300 x 350 x 50 mm | BNCM-D3CC | up to 15 beds | |
with four No.3 Digit display card, Acralic cover, in MS box of 300 x 450 x 50 mm | BNCM-D3CD | up to 20 beds | |
with fiveNo.3 Digit display card, Acralic cover, in MS box of 300 x 550 x 50 mm | BNCM-D3CE | up to 25 beds | |
with six No. 3 Digit display card, Acralic cover, in MS box of 600 x 475 x 50 mm | BNCM-D3CF | up to 30 beds | |
Data Logger Card |
Computer interferance card with softwar fitted in enclosure | BNCM-DLC-1 | up to 36 beds |
UPS sytem | Power supply with Automatic Battery charger, SMF 12 V. 7 AH battery | BNCMUPS1 | Up to 36 beds = 1 set |
Wires from bed to call station |
2 pair telephone wire | as per distance from beds to call station |